The red inner layer is made of insulation material to provide good insulation. The black outer layer is made of semi-conductive material to provide electrical shielding. Suitable for applications in medium voltage cable joints up to 42 kV. Shrink temperature: start at 90℃, and fully recovered at 130℃.
Technical Data-Inner Insulation
Property | Test Method | Standard Value |
Tensile Strength | ASTM-D-638 | ≥10MPa |
Elongation at Break | ASTM-D-638 | ≥350% |
Tensile Strength Variation After Heat Aging(130℃x168h) | ASTM-D-5510 | ≤±20% |
Elongation at Break Variation After Heat Aging(130℃x168h) | ASTM-D-5510 | ≤±20% |
Volume Resistivity | IEC 60093 | ≥1x1014Ω.cm |
Dielectric Strength | IEC 60243 | ≥20kV/mm |
Dielectric Constant | IEC 60250 | ≤4 |
Brittle Temperature | ISO 974 | -40℃ |
Hardness(Shore A) | ISO 868 | ≥80 |
Heat Shock | 160℃,4h | No Crack |
Longitudinal Shrinkage | ASTM-D-2671 | ≤10% |
Eccentricity | ASTM-D-2671 | ≤30% |
Technical Data-Outer Semi-conductive
Property | Test Method | Standard Value |
Tensile Strength | ASTM-D-638 | ≥10MPa |
Elongation at Break | ASTM-D-638 | ≥350% |
Tensile Strength Variation After Heat Aging(130℃x168h) | ASTM-D-5510 | ≤±20% |
Elongation at Break Variation After Heat Aging(130℃x168h) | ASTM-D-5510 | ≤±20% |
Volume Resistivity | IEC 60093 | ≥1x103Ω.cm |
Hardness(Shore A) | ISO 868 | ≥80 |
Heat Shock | 160℃,4h | No Crack |
Brittle Temperature | ISO 974 | -40℃ |
Longitudinal Shrinkage | ASTM-D-2671 | ≤10% |
Eccentricity | ASTM-D-2671 | ≤30% |
Spec. | As Supplied/mm | After Recovered/mm | Standard Length /mm | ||
Inner Diameter Min | Wall Thickness (±20%) | Inner Diameter Max | Wall Thickness (±10%) | ||
WDWT-30/12 | 30 | 2.8 | 12 | 5.8 | 300-1000 |
WDWT-35/13 | 35 | 2.5 | 13 | 5.8 | 300-1000 |
WDWT-45/17 | 45 | 2.3 | 17 | 5.8 | 300-1000 |
WDWT-55/21 | 55 | 2.2 | 21 | 5.8 | 300-1000 |
WDWT-65/26 | 65 | 2.3 | 26 | 5.8 | 300-1000 |
WDWT-85/30 | 85 | 2.7 | 30 | 7.2 | 300-1000 |
WDWT-100/38 | 100 | 2.9 | 38 | 7.2 | 300-1000 |
WDWT-120/45 | 120 | 2.9 | 45 | 7.2 | 300-1000 |