Your Location:Home > PRODUCTS > Separable Connectors Accessorie

Part No. picture Description Application Shrink Ratio Adhesive Lining Standards
Inner Cone Plug-in Serial up to 42kV( Insulated Insert) Inner Cone Plug-in Serial up to 42kV( Insulated Insert) Conforming to EN 50181 Connecting to seal insulated bushing used for spare outlet port
Inner Cone Plug-in Serial up to 42kV( Insulated Bushing) Inner Cone Plug-in Serial up to 42kV( Insulated Bushing) Conforming to EN 50181 Connecting to high voltage conductor of C-GIS cabinets or transformers Compact design, fully insulated and non-maintenance
Inner Cone Plug-in Serial up to 42kV (Termination) Inner Cone Plug-in Serial up to 42kV (Termination) Conforming to EN 50181 Dry interface Premould stress control cone of silicone rubber with 100% factory tested Tested according to IEC 60502 Metal protective shell on tail to provide great mechanical protection and fully shield Adopting one-piece compression structure of tail tube and spring to ensure enough interface force between the stress control cone and bushing Suitable for indoor& outdoor condition mated with C-GIS or transformers
Busbar Connecting System Busbar Connector Busbar connector system is made of silicone rubber, mainly applied for the connection for SF6 insulated switchgear with metal housing. Such special designed connector can be also made screened or unscreened, which can electrically insulate and mechanically seal the connecting busbar and switchgear. The connecting interface conforms to type C according to EN50180, EN 50181 and DIN 47636.
Energized Indicator & Fault Indicator & Cable Sheath Voltage Limiter (SVL) Energized Indicator Energized Indicator:Install at the test point to indicate the circuit energized status with flicker warning the energized circuit. Moreover, it is fully insulated and sealed with unlimited climate condition. Fault Indicator:Indicate the circuit status with flicker warning the faulted circuit to shorten the fault inspecting time. Cable Sheath Voltage Limiter (SVL):Use for single-core power cable route to restrict the inducted voltage on the cable metal sheath. It protects the sheath from breakdown by overvoltage.